top of page

FIRE PROTECTION & SAFETY SYSTEMS

We offer reliable fire protection and detection solutions designed to enhance workplace safety, protect valuable assets, and minimize fire-related risks. Our range of fire safety products includes automatic sprinkler systems and advanced smoke detection devices suitable for industrial, commercial, institutional, and residential applications.

​

Our fire protection solutions are designed to provide early fire detection, effective fire suppression, and integration with compatible fire alarm and safety infrastructure.

Automated Fire Sprinkler System

The system consists of sprinkler heads, a network of water distribution pipes, control valves, alarm valves, water supply arrangements, and associated accessories. When a fire generates sufficient heat, the heat-sensitive element in the sprinkler head activates, allowing water to discharge over the affected area.

​

Unlike general-purpose water discharge systems, individual automatic sprinkler heads typically activate independently when exposed to their specified operating temperature.

Key Product Features

  • Automatic heat-activated fire suppression.

  • Rapid response to elevated temperatures.

  • Individual sprinkler head activation.

  • Effective fire control and suppression.

  • Available in different temperature ratings.

  • Multiple sprinkler configurations.

  • Durable construction and corrosion-resistant options.

  • Suitable for integration with fire alarm and monitoring systems.

LF9W2eCexh2zLr6XykPu3-QX9bjM7F-02wLgMx8G5Ym0go9a7VeDCrFHCJIiIIMkblOQurAA-JB0_gQSTHzYRKVS9N

Types of Fire Sprinkler Systems We provide

1. Wet Pipe Sprinkler System

Pipes remain filled with pressurized water. When a sprinkler head activates, water is discharged immediately. Commonly used in commercial buildings, offices and industrial facilities where freezing is not a concern.


2. Dry Pipe Sprinkler System

Pipes contain pressurized air or nitrogen instead of water. When a sprinkler activates, pressure drops and the dry pipe valve allows water into the piping network. Suitable for areas exposed to freezing temperatures.

3. Pre-Action Sprinkler System

Uses a detection system to control water entry into the sprinkler piping. Commonly used in data centres, server rooms, museums and other water-sensitive environments.

4. Deluge Sprinkler SystemUses open sprinkler nozzles connected to a system controlled by a deluge valve. When activated, water is discharged through all open nozzles in the protected area. Suitable for high-hazard industrial applications.

Technical Specifications

Product Type: Automatic Fire Sprinkler

Available Types: Pendent, Upright, Sidewall, Concealed

System Type: Wet, Dry, Pre-Action, Deluge

Operating Mechanism: Heat-sensitive glass bulb / fusible element

Temperature Rating: 57°C, 68°C, 79°C, 93°C and others

K-Factor: Model dependent

Material: Brass / Stainless Steel

Finish: Chrome / Natural Brass / Other finishes

Connection: Threaded

Installation: Ceiling / Wall / Piping Network

Standards: Applicable UL Listed / FM Approved / IS requirements, depending on model

Applications

  • Manufacturing plants and factories.

  • Warehouses and logistics centres.

  • Commercial buildings and office complexes.

  • Shopping malls and retail facilities.

  • Hotels and hospitality facilities.

  • Hospitals and healthcare facilities.

  • Data centres and IT infrastructure.

  • Industrial processing facilities.

P6so2Drm8UIFEsNopymMyuwd1pyzGSIEvLWhgo3w7fsvQemlveiutAJH91gUSBPBj5AkgKl02vG7OAK4GjLRVbntIK

Smoke Detection System

Smoke detectors continuously monitor the surrounding environment and detect the presence of smoke using advanced sensing technologies. When smoke is detected, the device sends an alarm signal to the Fire Alarm Control Panel (FACP), which activates audible and visual warning devices to alert occupants.

​

Smoke detection systems help improve emergency response time, support safe evacuation, and minimize potential damage to buildings, equipment, and infrastructure.

Key Product Features

  • Early detection of smoke and potential fire hazards.

  • High-sensitivity sensing technology (model dependent).

  • Continuous environmental monitoring.

  • Automatic alarm signal transmission.

  • LED status and alarm indication.

  • Conventional and addressable configurations.

  • Integration with fire alarm control panels.

  • Compact design and easy installation.

  • Suitable for industrial and commercial applications.

Types of Smoke Detectors We provide

1. Photoelectric Smoke Detector

Uses optical sensing technology to detect smoke particles. Particularly suitable for detecting many slow-smouldering fires and commonly installed in offices, commercial buildings and residential spaces.

​

2. Ionization Smoke Detector

Uses an ionization chamber to detect changes caused by smoke particles. Traditionally used for detecting certain fast-flaming fires.


3. Addressable Smoke Detector

Communicates its unique device address to the fire alarm control panel, allowing the exact detector location to be identified during an alarm condition.

4. Conventional Smoke Detector

Connected to a conventional fire alarm control panel and reports an alarm condition through its assigned detection zone.

​

5. Beam Smoke Detector

Uses a projected light beam between a transmitter and receiver to detect smoke over a large area. Suitable for warehouses, industrial halls and buildings with high ceilings.

Technical Specifications

Product Type: Smoke Detector

Detection Technology: Photoelectric / Ionization / Beam / Aspirating

System Configuration: Conventional / Addressable

Operating Voltage: Model dependent, commonly 12V / 24V DC

Detection Method: Optical / Ionization / Light Obscuration

Indicator: LED Status Indicator

Alarm Output: Fire Alarm Control Panel

Mounting: Ceiling / Wall / Duct / Beam

Communication: Conventional or Addressable

Application: Industrial / Commercial / Residential

Standards: Applicable IS / EN / UL / NFPA requirements, depending on product

Applications

  • Industrial manufacturing facilities.

  • Warehouses and storage facilities.

  • Data centres and server rooms.

  • Office buildings and IT parks.

  • Hospitals and healthcare centres.

  • Hotels and commercial complexes.

  • Shopping malls and retail outlets.

  • Residential buildings and apartments.

Quality, Standards & Compliance

Both products should be selected, supplied and installed in accordance with applicable fire safety regulations, project specifications and manufacturer recommendations.

Relevant standards may include:
 

  • IS 15105 – Design and installation of fixed automatic sprinkler fire extinguishing systems.

  • IS 2189 – Selection, installation and maintenance of automatic fire detection and alarm systems.

  • NFPA 13 – Standard for the Installation of Sprinkler Systems.

  • NFPA 72 – National Fire Alarm and Signaling Code.

  • UL Listed / FM Approved – Product certification, where applicable to the specific model.


Actual certification and compliance must be verified against individual product datasheets.

About

Call: +91 91377 78295

Mumbai

SUBSCRIBE

Sign up to receive Techno Claive news and updates.

© 2035 by Techno Claive. Powered and secured by Ruh

bottom of page